Installing the 200-5100 Series AeroLoc
AeroLoc quarter turn fasteners are grip range sensitive. To ensure the panel seats correctly for a given grip range, it is important that any protrusions below the panel from the stud assembly fixings are taken into account.
If you are using the 200-1100 or 200-5100 Series, or if you are riveting any stud assembly from above - provision needs to be made for the stud assembly rivet bodies in the frame.
This can be achieved by rotating the receptacle fixing hole position by 35 degrees and drilling 2 x 5.0 mm clearance holes for the rivet bodies. (see Fig 2)